Complimentary shipping on qualifying orders · Easy returns · Secure checkout

Dell PERC 13 H975i Front RAID Controller

Adapter

Dell PERC 13 H975i Front RAID Controller

Price
Original price was: $260.27.Current price is: $130.14.

SKU:

G3778464033

Category:

Shopping information

Quick Specs

  • RAID Level: 0, 1, 5, 6, 10, 50, and 60
  • Non-RAID: Yes
  • Cache: No
  • PCIe: Gen 5 x16
  • Processor: Broadcom RAID-onchip, SAS5132W chipset
  • Battery Backup: Supercapacitor
  • Max no of VDs in RAID mode: 16/64
  • Max no of disk groups: 32
  • Max no of VDs per disk group: 8
  • Hot-swap devices supported: Yes
  • Drive sector size supported: 512B, 512e, and 4Kn
  • Storage Boot Support: UEFI-only

Supported Drives:

  • Gen3 (8 GT/s) NVMe
  • Gen4 (16 GT/s) NVMe
  • Gen5 (32 GT/s) NVMe

Max SAS/SATA disks:

  • Not supported

Max NVMe drives:

  • 16 drives per controller

Max physical disks:

  • 32 NVMe

Summary of RAID levels

Summary of RAID levels Following is a list of the RAID levels supported by the PERC 12 series of cards:

  • RAID 0 Uses disk striping to provide high data throughput, especially for large files in an environment that requires no data redundancy.
  • RAID 1 Uses disk mirroring so that data written to one physical disk is simultaneously written to another physical disk. RAID 1 is good for small databases or other applications that require small capacity and complete data redundancy.
  • RAID 5 Uses disk striping and parity data across all physical disks (distributed parity) to provide high data throughput and data redundancy, especially for small random access.
  • RAID 6 Is an extension of RAID 5 and uses an additional parity block. RAID 6 uses block-level striping with two parity blocks distributed across all member disks. RAID 6 provides protection against double disk failures, and failures while a single disk is rebuilding. If you are using only one array, deploying RAID 6 is more effective than deploying a hot spare disk.
  • RAID 10 Is a combination of RAID 0 and RAID 1, uses disk striping across mirrored disks. It provides high data throughput and complete data redundancy.
  • RAID 50 Is a combination of RAID 0 and RAID 5 where a RAID 0 array is striped across RAID 5 elements. RAID 50 requires at least six disks.
  • RAID 60 Is a combination of RAID 0 and RAID 6 where a RAID 0 array is striped across RAID 6 elements. RAID 60 requires at least eight disks.

Only logged in customers who have purchased this product may leave a review.

Keep exploring

More pieces selected to complement what you are viewing.

View all products